SALIENT FEATURES:
• PH MODE: Up to 5 points push-button calibration with auto-buffer recognition . Selectable pH buffer
Standards(USA, DIN, NIST. Automatically calculates and display electrode slope that help you decide
whether to replace pH electrode. calibration due reminder prompts you to calibration the meter
regularly.
• ORP MODE : Absolute or Relative mV measurements provides accurate ORP measured value 1 point
offset calibration allows user adjusts displayed to a known standard.
• CONDUCTIVITY /TDS/SALINITY/RESISTIVITY MODE : Up to 5-point push-button calibration allows
user to users customized calibration solutions. Default 10uS, 84uS 1413uS, 12.88mS and 111.8mS)
Adjustable TDS conversion factor ,cell constant ,temperature coefficients and normalization
temperature . (20°C or 25°C) Allows user selects linear or pure water temperature compensation
modes. In salinity measurement modes, Selectable practical salinity (PSU) or seawater measurements
standards. (ppt)
• Selectable either temperature units between degree Celsius (°C) and degree Fahrenheit (°F).
• Automatic temperature Compensation (ATS) ensure high accuracy of measurements..
• Automatic endpoint function freezes the stable measured value for easy reading and recording data.
• Help message as a operational guide to helps you understand how to use meter.
• Setup menu lets users customize the calibration points, stability condition of measurements, temp.
units and date/time to meet personal preference.
• Reset function allows user to return all setting to the factory default value.
• Expanded memory stores and recalls store upto 500 readings.
• Built-in real time clock stamp stored data to meet GLP standards.
• The multi-parameter water quality meter is equipped with an easy-read LCD display that used to show
the measured values and mode icons. The following table describes the function of each icon.
Model GMP-30
Make Galaxy
pH range: -2.000 ̴ 20.000 pH
Resolution: 0.001,0.01,0.01pH, Selectable
Accuracy: ±0.002 pH
Calibration Point: up to 5 points
pH buffer Option: USA,(pH 1.68, 4.01, 7.00 , 10.01, 12.45), NIST (pH 1.68/4.01/6.86/9.18/12.45), DIN (pH 1.09, 4.65, 6.79, 9.23, 12.75)
ORP (mV) Range/Calibration: 0 ̴ ±1999.9 mV/ 1 point
Resolution & Accuracy: 0.1,/1mV Selectable & ±0.2 mV
Measuring Mode: Absolute mV or Relative mV
Conductivity Range: 0 ̴ 200mS / cm
Resolution & Accuracy: 0.01 / 0.1 / 1 & ±0.5% F Full Scale
Cell Constant: 0.01/1/10 user defined
Temperature Coefficient: 0.0 ̴ 10.0 % per °C
Calibration Points: Up to 5 point
Calibration Solution: 10uS/cm, 48uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
Compensation Modes: Linear or pure water
TDS Range: 0 ̴ 10ppt (Max. 200ppt, Depending on factor setting
Resolution & Accuracy: 0.01/0.1/1 & ± 1% Full Scale
TDS Factor: 0.0 ̴ 1.0
Salinity Range: 0 ̴ 80ppt
Resolution & Accuracy: 0.01/0.1/1 & ± 1% Full Scale
Measurement Mode: Practical Salinity (PSU) or Seawater Measurement Standard (ppt)
Resistivity Range: 0 ̴ 100MΩ
Resolution & Accuracy: 1/0.1/0.01 & ± 1% Full size
Temp. Range: 0 ̴ 100 °C, /32 ̴ 212°F
Temp. Compensation: Automatic or Manual
Temp. Accuracy: ± 0.5 °C, ±0.9 °F